STEINEL US WLS 1 Ultrasonic Wall Switch Occupancy Sensor, White
A line voltage, single relay, Ultrasonic wall switch occupancy sensor to control lighting in commercial spaces. The photocell daylight option keeps the lighting load off when the light level is greater than the threshold level setting.
As part of our endeavour to deliver professional lighting and control solutions for the entire enterprise, Crestron is pleased to offer STEINEL PROFESSIONAL products, which are available for sale through authorized Crestron Commercial Lighting system integrators.
Based in Germany, STEINEL PROFESSIONAL has been manufacturing lighting controls for over 25 years. Their product offering includes a wide variety of controls and sensors for indoor and outdoor applications.
The US WLS 1 is a line voltage, single relay, Ultrasonic (40 kHz) wall switch occupancy sensor intended to control lighting in commercial spaces. Ultrasonic is used where the sensor will not have a clear line of site of the occupants in the desired coverage area. The hold OFF photocell daylight option will keep the lighting load off when the light level is greater than the threshold level setting. The convenient “Switch Link” feature enables up to four sensors to link together for pier to pier grouping achieving expanded detection zones and multiway switching.
The typical application is for small offices, restrooms with two stalls and utility/storage rooms. For best performance use this sensor in enclosed spaces no larger than 15’ x 15’.
For additional information and resources, please visit http://www.steinel.net/US_WLS_1.
Key Features
- 40 kHz ultrasonic wall switch occupancy sensor
- Adjustable ultrasonic reach setting from 25% to 100%
- Line voltage lighting control (120/230/277 VAC, 50/60 Hz)
- 180° coverage pattern
- Manual ON or Automatic ON option
- Light level feature keeps lights OFF when sufficient daylight is present
- Mounts to a single-gang NEMA-style, standard switch box & decorator-style wall plate by others
- “Switch Link” communication allows for up to 4 sensors to be grouped together
- IQ Mode dynamically adjusts the ‘ON’ time delay by learning individual room occupancy
- Walk through mode option will switch the load OFF in 3 minutes if no additional detection occurs after the first 30 seconds
- Audible alert feature provides an audible warning that the load will shut-OFF in 10 seconds unless additional motion is detected
- Visible alert feature provides a momentary OFF/ON blink, warning that the load will shut OFF in 10 seconds unless additional motion is detected
- Service mode option deactivates the automated functions of the sensor and the load is only manually controlled using the ON/OFF button
|
Voltage |
120/230/277 VAC, 50/60 Hz |
|
Load Rating |
tungsten, magnetic or electronic ballast: 0-800 watts @ 120/230/277 VAC, 50/60 Hz;
CFL or LED electronic ballasts: 0-600 watts @ 120/230/277 VAC, 50/60 Hz;
1/6 hp @ 120/230/277 VAC, 50/60 Hz |
|
Sensing Technology |
40 kHz ultrasonic |
|
Ultrasonic Coverage at 1.2 m / 4 ft Mounting Height |
180 degree coverage pattern;
minor motion: max. 8 x 8 m (64 sq.m.), max. 18 x 12 ft (216 sq.ft.);
radially: max. 7 m (77 sq.m.) 24 ft (904 sq.ft.);
tangentially: max. 7 m (77 sq.m.) 24 ft (904 sq.ft.) |
|
Time Setting |
IQ/Test, 5, 15, 30 minutes;
IQ Mode: Dynamically adjusts the 'ON' time delay by learning individual room occupancy;
Test Mode: Time delay defaults to 5 seconds and all loads are switched on/off by motion detection; After 5 minutes the time delay reverts to the IQ Mode |
|
Reach Setting |
Adjustable from 25 percent to 100 percent |
|
Light Level Setting |
80 - 2000 lux / 8 - 200 fc, keeps lights OFF when sufficient daylight is present |
|
Dip Switch Settings |
Manual ON or Automatic ON option;
Walk Through Mode: Switch the load OFF in 3 minutes if no additional detection occurs after the first 30 seconds;
Audible Alert: Provides an audible warning that the load will shut-OFF in 10 seconds unless additional motion is detected;
Visible Alert: Provides a momentary OFF/ON blink, warning that the load will shut OFF in 10 seconds unless additional motion is detected |
|
Service mode |
Deactivates the automated functions of the sensor and the load is only manually controlled using the ON/OFF button |
|
Switching |
Performed at, or close to the zero-cross of the AC waveform in order to improve relay performance |
|
Switch Link |
Allows communication of sensors for 2-way, 3-way, and 4-way switching |
|
Real-time motion indicator LED |
Visible from the front of unit while in test mode |
|
Environment |
IP20 rated, 0°C to +40°C, 32°F to +104°F |
|
Mounting |
single-gang NEMA-style switch box (standard switch box) & decorator-style wall plate by others |
|
Dimensions |
105 x 44.1 x 45.1 mm, 4.13 x 1.74 x 1.78 in, (LxWxD) |
|
Certifications |
C-UL-US Listed, RoHS compliant, California compliant |